FTIR Dry cabinet Moisture-proof Box Dehumidifier

1.Humidity control range: 25RH% - 50RH%, front-mounted LCD screen with dual display of temperature and humidity.

2.Opening and closing method: The upper cover is designed with a damping hinge for opening and closing. This effectively utilizes the upper space, avoiding the space waste and operational inconvenience caused by double-door design.

3.Line design: Hidden protection design for wiring and power supply lines, and addition of protective boards for PCB circuit boards.

4.Dehumidification system: The intelligent humidity sensing module uses a microcomputer program system with a recyclable and regenerative moisture-absorbing molecular layer membrane to control humidity. If the humidity inside the warehouse exceeds the set humidity level, the system will automatically start dehumidification. There are no consumables.

5.Operation status: Even in the event of power failure, it has the moisture absorption protection function and can still utilize the chemical moisture absorption compensation function to continue dehumidification. The humidity increase within 24 hours will not exceed 10%.

Product Detail

FTIR Dry Cabinet Moisture-Proof Box & Dehumidifier

The MRD series infrared spectrometer electronic moisture proof cabinet is equipped with a high-performance electronic dehumidifier core and a microcomputer-controlled humidity system. It provides energy-saving, noise-free operation with a clear digital humidity display. Designed as a dedicated accessory for Fourier transform infrared spectrometers, this moisture proof box offers reliable dust-proof and moisture-proof protection, significantly extending the service life of the instrument’s core components.

Notes:

  1. RH (Relative Humidity) indicates moisture level; higher numbers mean higher humidity. Typical control range is 25%–55% RH.
  2. Do not store corrosive, explosive, volatile, or flammable items.
  3. Avoid installation in direct sunlight.
  4. Keep away from heat sources, high humidity areas, or air vents.
  5. Use 220v alternating current. It is recommended to use an independent socket.

FTIR Dry Cabinet Dimension

FTIR Dry Cabinet Dimension
Model External dimension(L*W*H) Internal dimension(L*W*H) Net Weight
MRD-100S 620*670*410mm 520*530*340mm 21.5kg
MRD-200S 710*670*410mm 610*540*340mm 23kg
MRD-200S-JG50 710*670*460mm 610*540*390mm 27Kg
MRD-300S 890*830*410mm 750*740*340mm 32kg
MRD-300S-JG50 890*830*460mm 750*740*390mm 37kg
MRD-300S Plus 950*900*480mm 800*790*400mm 42kg
MRD-400 840*1100*540mm 760*950*420mm 50kg
Note: External dimensions include handles, rubber plugs, desiccant boxes and bases.

MRD Series Intelligent Infrared Spectrometer Moisture-Proof Box

The MRD series intelligent infrared spectrometer electronic moisture proof storage boxes are specially designed dehumidification devices for Fourier infrared spectrometers. They effectively protect the interferometer and prevent damage to the detector caused by deliquescence. Compliant with PC/JEDEC J-STD-033B standards (relative humidity ≤50% RH), these boxes monitor humidity in real time and automatically activate the dehumidification function when levels exceed the set threshold. With no consumables required and low energy consumption, the MRD series provides reliable, long-term protection for Fourier infrared spectrometers worldwide.

Structure & Features

  • Large visual viewing window for easy observation.
  • Removable rubber plug design to accommodate original data cables.
  • Built-in three-way switching power supply for stable operation.
  • Base plate made of 5 mm thick rolled steel for durability.
  • Gravity upper cover with inlet sealing strip for secure closure.
  • Intelligent humidity sensing module with automatic dehumidification when humidity exceeds set levels.
  • Hydraulic hover support technology for smooth operation.
  • Imported compound sealing rubber strip ensures airtightness.
  • PCB microcomputer control system with front LCD screen for real-time temperature and humidity display.

This airtight moisture proof container is the perfect solution for laboratories seeking dependable, automated protection for their FTIR instruments, ensuring optimal performance and extended equipment life.

Product Feature

  • Humidity control range: 25% RH – 50% RH, with front LCD screen displaying both temperature and humidity.

  • Opening design: The top cover with a damping hinge allows smooth opening and closing, effectively utilizing upper space while avoiding waste and inconvenience caused by side-opening doors.

  • Cable routing design: Hidden protection design for cables and power supply lines, with an added protective plate for the PCB circuit board.

  • Dehumidification system: Equipped with an intelligent humidity sensing module, using a renewable cycle moisture-absorption sub-layer film. The microcomputer control system regulates humidity automatically. When the humidity inside exceeds the set level, the system initiates dehumidification without consumables.

  • Operation: With power-off hygroscopic protection, the chemical hygroscopic material continues to function, ensuring dehumidification. Within 24 hours of power-off, the humidity rise does not exceed 10%.

About Hench Technology

Hench Technology Co., Ltd., based in Tianjin, China, specializes in the design and manufacturing of infrared spectroscopy sample preparation equipment. Their product line includes IR hydraulic presses, molds, heated dies, and full accessory sets. As a trusted lab supplies manufacturer, Hench provides durable, high-performance solutions for laboratories worldwide.

Infrared spectrometer electronic moisture-proof cabinet manufacturer Infrared moisture-proof cabinet application Infrared moisture-proof cabinet parameters Infrared Moisture-proof Cabinet Analysis Infrared Moisture-proof Cabinet Real Photo Features of Infrared Damp-proof Cabinet Infrared moisture-proof cabinet case site Infrared moisture-proof cabinet factory shooting scene