2/10/20/30/40/60-ton Fully Automatic Powder Tablet Press Machine HAP-S
Fully Automatic Powder Tablet Press Machine
The HAP series automatic hydraulic press with hydraulic drive is mainly used for powder molding sample preparation and is widely applied in X-ray fluorescence, calcium and iron analysis, superconductivity, building materials, ceramics, cement, and other material field research. This product provides precise control to solve the problem of the 6 mm die under the automatic pellet press, and it also meets customers’ multi-stage pressure requirements while incorporating numerous safety features.
Key Features
Advanced Hydraulic Press Technology
At the core of the HAP-30S is its hydraulic press system, which provides uniform pressure distribution across the die, ensuring high-density tablets with minimal variation. This technology is a testament to Hench's commitment to quality and innovation in laboratory equipment. For a broader range of hydraulic solutions, explore our Hydraulic Press Series.
Tailored for Laboratory Excellence
The HAP-30S is meticulously crafted to meet the rigorous demands of laboratory environments. Its compact design, combined with advanced features, makes it an indispensable tool for researchers and technicians seeking reliability and precision. Discover more about our comprehensive lab supplies to enhance your laboratory's capabilities.
Intelligent Control and Safety Features
Equipped with the Savta intelligent program control system, the HAP-30S allows for up to 15 programmable pressure stages, offering flexibility for various sample types. Safety is paramount; the machine includes a 7" touch LCD screen, emergency stop functions, and overpressure protection mechanisms. For those interested in automated solutions, our Automatic Hydraulic Press category provides a range of options to suit diverse needs.
Product Description
| Instrument model | HAP-2S | HAP-10S | HAP-20S | HAP-30S | HAP-40S | HAP-60S |
| pressure range | 0.2-2.0T | 0.2-10.0T | 0.2-20.0T | 0.2-30.0T | 1.0-40.0T | 1.0-60.0T |
| Cylinder diameter | Φ55mm | Φ65mm | Φ95mm | Φ110mm | Φ130mm | Φ150mm |
| automatic control | Savta intelligent program is used to control the five-stage pressurization | |||||
| Pressure mode | Automatic pressure replenishment - timed pressure retention - automatic pressure relief. | |||||
| Holding time | Unlimited time (seconds) | |||||
| Pressure conversion | The system automatically converts the sample pressure (overpressure warning) | |||||
| Device display | 7* touch screen | |||||
| Equipment protection | 100mm chrome steel side panel + 6mm plexiglass protective door | |||||
| Limit protection | Cylinder above the limit height automatic pressure relief | |||||
| Host protection | Automatic pressure relief program is initiated when the upper pressure of the unit is exceeded | |||||
| data administration | It can store 10,000 historical operation records, and can be imported to the U disk for storage | |||||
| Cylinder path | ≤30mm | ≤50mm | ||||
| work space | 140×165mm | 175×185mm | 185×225mm | |||
| boundary dimension | 230×390×425mm | 280×460×555mm | 300×520×585mm | |||
| device power supply | 220V/60Hz | 220V/60Hz | 220V/60Hz | |||
| Installation (unit) weight | 96Kg | 152Kg | 183Kg | |||
This product can be customized or improved according to customer needs*
Operating Procedure for Automatic Hydraulic Press Machine
- Load Sample and Assemble Mold
Load the sample into the mold and assemble it securely. Ensure all components are aligned correctly for accurate pressing. - Place Mold in Hydraulic Press
Insert the mold into the laboratory hydraulic press and tighten the lead screw to secure the setup. - Set Pressure Parameters
Press the Setting button to enter the pressure setting screen. Configure the target pressure and die diameter according to your sample requirements. - Start Pressurization
Return to the home screen and press Start. The electric hydraulic press will gradually increase pressure to the set target. Once reached, the system automatically maintains the pressure, then safely relieves it after completion. - Remove Sample
Loosen the top screw and remove the mold. Unplug the lower base, invert the mold, and place it into the release sleeve. Manually rotate the upper lead screw to remove the film and carefully take out the sample. - Check Sample
Inspect the sample for proper shape, surface finish, and dimensional accuracy before proceeding to further tests or analysis.
Detail Description
- High-Level System Settings: Switchable English and Chinese interfaces for easy operation.
- Historical Data: Stores up to 10,000 operation records, which can be exported to a USB disk.
- Multi-Stage Pressurization: Configure up to five stages of pressure in the Pressurization Phase for complex experiments.
- Mold Flexibility: Supports Round, Square, or Opposite mold types with adjustable die diameters.
Operation Interface
Setting
Enter the Setting interface to adjust pressure, mold type, and sample parameters.
Demould
Press Release to start. The device automatically stops and relieves pressure when the set limit is reached. Manual screw operation is also available for precise control.
Data Administration
Press Data Management to view experiment parameters and historical records. Data can be exported to a USB disk for further analysis.
Pressurization Phase
Configure up to five stages of pressure in the setting interface for complex sample preparation.
Mold Type and Die Diameter
Select Round, Square, or Opposite mold type. Press Mold Diameter to set the sample size, then click Save to start the preparation cycle.
About Hench Technology Co., Ltd.
Hench Technology Co., Ltd. is a leading manufacturer specializing in high-quality laboratory equipment. With a focus on innovation and customer satisfaction, Hench offers a wide array of products, including hydraulic presses and lab supplies, to support scientific research and industrial applications. As trusted hydraulic press suppliers, we are committed to delivering excellence and reliability in every product.