{"id":6449,"date":"2026-04-24T08:51:36","date_gmt":"2026-04-24T08:51:36","guid":{"rendered":"https:\/\/www.hcftir.com\/?p=6449"},"modified":"2026-04-24T08:51:37","modified_gmt":"2026-04-24T08:51:37","slug":"protecting-precision-hench-infrared-dehumidifying-cabinets-for-bruker-ftir-spectrometers","status":"publish","type":"post","link":"https:\/\/www.hcftir.com\/ja\/protecting-precision-hench-infrared-dehumidifying-cabinets-for-bruker-ftir-spectrometers-article\/","title":{"rendered":"\u7cbe\u5bc6\u3055\u3092\u5b88\u308b\u30d6\u30eb\u30ab\u30fcFTIR\u5206\u5149\u8a08\u7528\u30d8\u30f3\u30c1\u9664\u6e7f\u30ad\u30e3\u30d3\u30cd\u30c3\u30c8"},"content":{"rendered":"<p>\u4e16\u754c\u3092\u30ea\u30fc\u30c9\u3059\u308b\u5206\u6790\u6a5f\u5668\u3068\u3057\u3066\u3001 <strong>\u30d6\u30eb\u30ab\u30fcFTIR\u5206\u5149\u8a08<\/strong> \u306f\u3001\u88fd\u85ac\u3001\u5316\u5b66\u5de5\u5b66\u3001\u79d1\u5b66\u7814\u7a76\u306b\u4e0d\u53ef\u6b20\u306a\u3082\u306e\u3067\u3042\u308b\u3002\u3057\u304b\u3057\u3001\u305d\u306e\u6838\u3068\u306a\u308b <strong>\u30d3\u30fc\u30e0\u30b9\u30d7\u30ea\u30c3\u30bf\u30fc\u3001KBr\uff08\u81ed\u5316\u30ab\u30ea\u30a6\u30e0\uff09\u30a6\u30a4\u30f3\u30c9\u30a6\u3001\u5e72\u6e09\u8a08<\/strong>-\u306f\u6975\u3081\u3066\u5438\u6e7f\u6027\u304c\u9ad8\u3044\u3002\u904e\u5ea6\u306e\u6e7f\u6c17\u306f\u6f6e\u89e3\u3001\u5149\u8def\u306e\u9038\u8131\u3001\u4e0d\u53ef\u9006\u7684\u306a\u640d\u50b7\u3092\u5f15\u304d\u8d77\u3053\u3057\u3001\u591a\u304f\u306e\u5834\u5408\u3001\u6570\u4e07\u30c9\u30eb\u3092\u8d85\u3048\u308b\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u8cbb\u7528\u304c\u767a\u751f\u3059\u308b\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/www.hcftir.com\/wp-content\/uploads\/2026\/04\/Hench-Infrared-Dehumidifying-Cabinets-for-Bruker-FTIR-Spectrometers-2-1024x768.webp\" alt=\"Bruker FTIR \u306e\u5206\u5149\u8a08\u306e\u305f\u3081\u306e Hench \u306e\u8d64\u5916\u7dda\u9664\u6e7f\u306e\u30ad\u30e3\u30d3\u30cd\u30c3\u30c8\" class=\"wp-image-6450\" srcset=\"https:\/\/www.hcftir.com\/wp-content\/uploads\/2026\/04\/Hench-Infrared-Dehumidifying-Cabinets-for-Bruker-FTIR-Spectrometers-2-1024x768.webp 1024w, https:\/\/www.hcftir.com\/wp-content\/uploads\/2026\/04\/Hench-Infrared-Dehumidifying-Cabinets-for-Bruker-FTIR-Spectrometers-2-300x225.webp 300w, https:\/\/www.hcftir.com\/wp-content\/uploads\/2026\/04\/Hench-Infrared-Dehumidifying-Cabinets-for-Bruker-FTIR-Spectrometers-2-768x576.webp 768w, https:\/\/www.hcftir.com\/wp-content\/uploads\/2026\/04\/Hench-Infrared-Dehumidifying-Cabinets-for-Bruker-FTIR-Spectrometers-2-16x12.webp 16w, https:\/\/www.hcftir.com\/wp-content\/uploads\/2026\/04\/Hench-Infrared-Dehumidifying-Cabinets-for-Bruker-FTIR-Spectrometers-2.webp 1267w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p>\u306b\u3064\u3044\u3066 <strong>\u30d8\u30f3\u30c1MRD\/LAG\u30b7\u30ea\u30fc\u30ba\u8d64\u5916\u7dda <a href=\"http:\/\/infrared dehumidifying cabinet\">\u96fb\u5b50\u9664\u6e7f\u30ad\u30e3\u30d3\u30cd\u30c3\u30c8<\/a><\/strong> \u306f\u3001FTIR\u30b7\u30b9\u30c6\u30e0\u306e\u5168\u30e9\u30a4\u30d5\u30b5\u30a4\u30af\u30eb\u4fdd\u8b77\u306e\u305f\u3081\u306b\u7279\u5225\u306b\u8a2d\u8a08\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u6b63\u78ba\u306a\u6e7f\u5ea6\u5236\u5fa1\u3068\u30b7\u30fc\u30e0\u30ec\u30b9\u306a\u7d71\u5408\u3092\u63d0\u4f9b\u3059\u308b\u3053\u3068\u3067\u3001\u30d8\u30f3\u30c1\u306f\u4e16\u754c\u4e2d\u306e\u30d6\u30eb\u30ab\u30fc\u5206\u5149\u8a08\u306e\u4fe1\u983c\u3067\u304d\u308b\u4fdd\u8b77\u8005\u3068\u306a\u308a\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u30b3\u30a2\u30fb\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u306e\u5229\u70b9<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">1.\u8d85\u7cbe\u5bc6\u6e7f\u5ea6\u30b3\u30f3\u30c8\u30ed\u30fc\u30eb<\/h3>\n\n\n\n<p>\u30d6\u30eb\u30ab\u30fc\u5206\u5149\u8a08\u306f\u901a\u5e38\u3001\u4ee5\u4e0b\u306e\u9593\u306e\u4fdd\u7ba1\u74b0\u5883\u3092\u5fc5\u8981\u3068\u3057\u307e\u3059\u3002 <strong>30%-40% rh<\/strong>.\u30d8\u30f3\u30c1\u30fb\u30ad\u30e3\u30d3\u30cd\u30c3\u30c8\u306f\u3001\u5e45\u5e83\u3044\u8abf\u6574\u7bc4\u56f2\u3092\u63d0\u4f9b\u3057\u307e\u3059\u3002 <strong>20%-50% RH<\/strong> \u306e\u7cbe\u5ea6\u3067 <strong>\u00b13% RH<\/strong>.\u3059\u3050\u306b\u98fd\u548c\u3057\u3066\u3057\u307e\u3046\u5f93\u6765\u306e\u4e7e\u71e5\u5264\u3068\u306f\u7570\u306a\u308a\u3001\u30d8\u30f3\u30c1\u306f <strong>\u518d\u751f\u53ef\u80fd\u30e2\u30ec\u30ad\u30e5\u30e9\u30fc\u30b7\u30fc\u30d6\uff0b\u56fa\u4f53\u96fb\u89e3\u9664\u6e7f<\/strong> \u30c6\u30af\u30ce\u30ed\u30b8\u30fc\u3092\u63a1\u7528\u3057\u3066\u3044\u308b\u3002\u3053\u306e\u30b7\u30b9\u30c6\u30e0\u306f\u81ea\u52d5\u7684\u306b\u6e7f\u6c17\u3092\u611f\u77e5\u3057\u3001\u6c34\u5206\u5b50\u3092\u30ac\u30b9\u5316\u3057\u3001\u7d50\u9732\u3084\u6c34\u6ef4\u306a\u3057\u306b\u6392\u51fa\u3059\u308b\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/www.hcftir.com\/wp-content\/uploads\/2026\/04\/Hench-Infrared-Dehumidifying-Cabinets-for-Bruker-FTIR-Spectrometers-1024x768.webp\" alt=\"Bruker FTIR \u306e\u5206\u5149\u8a08\u306e\u305f\u3081\u306e Hench \u306e\u8d64\u5916\u7dda\u9664\u6e7f\u306e\u30ad\u30e3\u30d3\u30cd\u30c3\u30c8\" class=\"wp-image-6454\" srcset=\"https:\/\/www.hcftir.com\/wp-content\/uploads\/2026\/04\/Hench-Infrared-Dehumidifying-Cabinets-for-Bruker-FTIR-Spectrometers-1024x768.webp 1024w, https:\/\/www.hcftir.com\/wp-content\/uploads\/2026\/04\/Hench-Infrared-Dehumidifying-Cabinets-for-Bruker-FTIR-Spectrometers-300x225.webp 300w, https:\/\/www.hcftir.com\/wp-content\/uploads\/2026\/04\/Hench-Infrared-Dehumidifying-Cabinets-for-Bruker-FTIR-Spectrometers-768x576.webp 768w, https:\/\/www.hcftir.com\/wp-content\/uploads\/2026\/04\/Hench-Infrared-Dehumidifying-Cabinets-for-Bruker-FTIR-Spectrometers-16x12.webp 16w, https:\/\/www.hcftir.com\/wp-content\/uploads\/2026\/04\/Hench-Infrared-Dehumidifying-Cabinets-for-Bruker-FTIR-Spectrometers.webp 1267w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">2.\u30d6\u30eb\u30ab\u30fc\u30b7\u30b9\u30c6\u30e0\u3068\u306e\u30b7\u30fc\u30e0\u30ec\u30b9\u306a\u7d71\u5408<\/h3>\n\n\n\n<p>\u5f53\u793e\u306e\u30ad\u30e3\u30d3\u30cd\u30c3\u30c8\u306f\u3001\u4ee5\u4e0b\u306e\u30d6\u30eb\u30ab\u30fc\u88fd\u54c1\u30b7\u30ea\u30fc\u30ba\u3068\u6df1\u3044\u4e92\u63db\u6027\u304c\u3042\u308a\u307e\u3059\u3002 <strong>TENSOR II\u3068INVENIO<\/strong> \u306e\u30e2\u30c7\u30eb\u3060\u3002<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u30bc\u30ed\u5206\u89e3\u4fdd\u8b77\uff1a<\/strong> \u5206\u5149\u8a08\u306f\u3001\u5206\u89e3\u3059\u308b\u3053\u3068\u306a\u304f\u5bc6\u9589\u3055\u308c\u305f\u74b0\u5883\u5185\u306b\u53ce\u7d0d\u3057\u3001\u64cd\u4f5c\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u308b\u3002<\/li>\n\n\n\n<li><strong>\u30b9\u30de\u30fc\u30c8\u306a\u30c7\u30b6\u30a4\u30f3\uff1a<\/strong> \u30b1\u30fc\u30d6\u30eb\u30dd\u30fc\u30c8\u3068\u96fb\u6e90\u30bd\u30b1\u30c3\u30c8\u3092\u5185\u8535\u3057\u3066\u304a\u308a\u3001\u6a5f\u5668\u306e\u63a5\u7d9a\u6027\u304c\u640d\u306a\u308f\u308c\u308b\u3053\u3068\u306f\u3042\u308a\u307e\u305b\u3093\u3002<\/li>\n\n\n\n<li><strong>\u30ab\u30b9\u30bf\u30de\u30a4\u30ba\u53ef\u80fd\u306a\u30ec\u30a4\u30a2\u30a6\u30c8\uff1a<\/strong> \u8907\u6570\u306e\u6e2c\u5b9a\u5668\u3084\u30d0\u30eb\u30af\u5149\u5b66\u30a2\u30af\u30bb\u30b5\u30ea\u30fc\u3092\u53ce\u7d0d\u3067\u304d\u308b\u3088\u3046\u3001\u30b9\u30d7\u30ea\u30c3\u30c8\u30bf\u30a4\u30d7\u307e\u305f\u306f\u30ab\u30b9\u30bf\u30e0\u30b5\u30a4\u30ba\u306e\u30c7\u30b6\u30a4\u30f3\u3092\u3054\u7528\u610f\u3002<\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/www.hcftir.com\/wp-content\/uploads\/2026\/04\/Hench-Infrared-Dehumidifying-Cabinets-for-Bruker-FTIR-Spectrometers-3-1024x768.webp\" alt=\"Bruker FTIR \u306e\u5206\u5149\u8a08\u306e\u305f\u3081\u306e Hench \u306e\u8d64\u5916\u7dda\u9664\u6e7f\u306e\u30ad\u30e3\u30d3\u30cd\u30c3\u30c8\" class=\"wp-image-6451\" srcset=\"https:\/\/www.hcftir.com\/wp-content\/uploads\/2026\/04\/Hench-Infrared-Dehumidifying-Cabinets-for-Bruker-FTIR-Spectrometers-3-1024x768.webp 1024w, https:\/\/www.hcftir.com\/wp-content\/uploads\/2026\/04\/Hench-Infrared-Dehumidifying-Cabinets-for-Bruker-FTIR-Spectrometers-3-300x225.webp 300w, https:\/\/www.hcftir.com\/wp-content\/uploads\/2026\/04\/Hench-Infrared-Dehumidifying-Cabinets-for-Bruker-FTIR-Spectrometers-3-768x576.webp 768w, https:\/\/www.hcftir.com\/wp-content\/uploads\/2026\/04\/Hench-Infrared-Dehumidifying-Cabinets-for-Bruker-FTIR-Spectrometers-3-16x12.webp 16w, https:\/\/www.hcftir.com\/wp-content\/uploads\/2026\/04\/Hench-Infrared-Dehumidifying-Cabinets-for-Bruker-FTIR-Spectrometers-3.webp 1267w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">3.\u7814\u7a76\u5ba4\u30ec\u30d9\u30eb\u306e\u69cb\u9020\u3068\u5b89\u5168\u6027<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u5de5\u696d\u7684\u8010\u4e45\u6027\uff1a<\/strong> \u3067\u69cb\u7bc9\u3055\u308c\u3066\u3044\u308b\u3002 <strong>1.5mm\u5f37\u5316\u51b7\u5ef6\u92fc\u677f<\/strong> \u305d\u3057\u3066\u5e2f\u96fb\u9632\u6b62\u3001\u96e3\u71c3\u30b3\u30fc\u30c6\u30a3\u30f3\u30b0\u3067\u4ed5\u4e0a\u3052\u3089\u308c\u3066\u3044\u308b\u3002<\/li>\n\n\n\n<li><strong>\u512a\u308c\u305f\u5bc6\u9589\u6027\uff1a<\/strong> \u9ad8\u7d1a\u30b7\u30ea\u30b3\u30f3\u30fb\u30ac\u30b9\u30b1\u30c3\u30c8\u3068\u6c17\u5bc6\u30af\u30ed\u30fc\u30b8\u30e3\u30fc\u30fb\u30b7\u30b9\u30c6\u30e0\u306b\u3088\u308a\u3001\u5916\u90e8\u306e\u6e7f\u6c17\u3084\u30db\u30b3\u30ea\u3092\u906e\u65ad\u3002<\/li>\n\n\n\n<li><strong>24\u6642\u9593365\u65e5\u306e\u96fb\u6e90\u30aa\u30d5\u4fdd\u8b77\uff1a<\/strong> \u9ad8\u3044\u30a8\u30cd\u30eb\u30ae\u30fc\u52b9\u7387\uff08\u308f\u305a\u304b <strong>0.3kWh\/\u65e5<\/strong>)\u3001\u30ad\u30e3\u30d3\u30cd\u30c3\u30c8\u306f\u5b89\u5168\u306a\u6e7f\u5ea6\u30ec\u30d9\u30eb\u3092\u7dad\u6301\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002 <strong>\u505c\u96fb\u6642\u3067\u3082\u6700\u592724\u6642\u9593\u4f7f\u7528\u53ef\u80fd<\/strong>\u591c\u9593\u306e\u6e7f\u5ea6\u4e0a\u6607\u3092\u306a\u304f\u3059\u3002<\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"767\" src=\"https:\/\/www.hcftir.com\/wp-content\/uploads\/2026\/04\/Hench-Infrared-Dehumidifying-Cabinets-for-Bruker-FTIR-Spectrometers-5-1024x767.webp\" alt=\"Bruker FTIR \u306e\u5206\u5149\u8a08\u306e\u305f\u3081\u306e Hench \u306e\u8d64\u5916\u7dda\u9664\u6e7f\u306e\u30ad\u30e3\u30d3\u30cd\u30c3\u30c8\" class=\"wp-image-6453\" srcset=\"https:\/\/www.hcftir.com\/wp-content\/uploads\/2026\/04\/Hench-Infrared-Dehumidifying-Cabinets-for-Bruker-FTIR-Spectrometers-5-1024x767.webp 1024w, https:\/\/www.hcftir.com\/wp-content\/uploads\/2026\/04\/Hench-Infrared-Dehumidifying-Cabinets-for-Bruker-FTIR-Spectrometers-5-300x225.webp 300w, https:\/\/www.hcftir.com\/wp-content\/uploads\/2026\/04\/Hench-Infrared-Dehumidifying-Cabinets-for-Bruker-FTIR-Spectrometers-5-768x575.webp 768w, https:\/\/www.hcftir.com\/wp-content\/uploads\/2026\/04\/Hench-Infrared-Dehumidifying-Cabinets-for-Bruker-FTIR-Spectrometers-5-16x12.webp 16w, https:\/\/www.hcftir.com\/wp-content\/uploads\/2026\/04\/Hench-Infrared-Dehumidifying-Cabinets-for-Bruker-FTIR-Spectrometers-5.webp 1269w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">\u5b9f\u969b\u306e\u30b1\u30fc\u30b9\u30b9\u30bf\u30c7\u30a3\u5927\u5b66\u306e\u7814\u7a76\u5ba4<\/h2>\n\n\n\n<p>3\u3064\u306e\u7814\u7a76\u6240\u3092\u904b\u55b6\u3059\u308b\u8457\u540d\u306a\u5927\u5b66\u306e\u7814\u7a76\u5ba4 <strong>\u30d6\u30eb\u30ab\u30fc TENSOR II<\/strong> \u30e6\u30cb\u30c3\u30c8\u306f\u983b\u7e41\u306b\u30c0\u30a6\u30f3\u30bf\u30a4\u30e0\u306b\u76f4\u9762\u3057\u305f\u3002\u30e2\u30f3\u30b9\u30fc\u30f3\u30b7\u30fc\u30ba\u30f3\uff08\u6e7f\u5ea660%\u4ee5\u4e0a\uff09\u306b\u306f\u3001KBr\u7a93\u304c\u4f55\u5ea6\u3082\u66c7\u308a\u3001\u5e72\u6e09\u8a08\u306e\u6545\u969c\u7387\u304c\u6025\u5897\u3057\u305f\u3002 <strong>$7,000\uff0850,000\u5143\uff09<\/strong> \u5e74\u9593\u4fee\u7406\u8cbb<\/p>\n\n\n\n<p><strong>\u89e3\u6c7a\u7b56<\/strong> \u30e9\u30dc\u304c\u8a2d\u7f6e\u3057\u305f <strong>\u30d8\u30f3\u30c1MRD\u30b7\u30ea\u30fc\u30ba<\/strong> \u3067\u6e7f\u5ea6\u3092\u5b89\u5b9a\u3055\u305b\u308b\u3002 <strong>35% \u00b13% RH<\/strong>.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u7d50\u679c<\/strong> KBr\u30a6\u30a3\u30f3\u30c9\u30a6\u306e\u5bff\u547d\u306f\u6b21\u306e\u3088\u3046\u306b\u5ef6\u3073\u305f\u3002 <strong>2-3x<\/strong>.<\/li>\n\n\n\n<li><strong>\u4fe1\u983c\u6027\uff1a<\/strong> \u5e72\u6e09\u3068\u30d3\u30fc\u30e0\u30b9\u30d7\u30ea\u30c3\u30bf\u30fc\u306e\u6545\u969c\u304c\u6e1b\u5c11 <strong>80%<\/strong>.<\/li>\n\n\n\n<li><strong>ROI\uff1a<\/strong> \u3053\u306e\u7814\u7a76\u5ba4\u3067\u306f\u3001\u7d04 <strong>$4,500\/\u5e74<\/strong> \u30c7\u30fc\u30bf\u306e\u518d\u73fe\u6027\u3068\u7cbe\u5ea6\u3092\u5927\u5e45\u306b\u5411\u4e0a\u3055\u305b\u306a\u304c\u3089\u3001\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u3084\u6d88\u8017\u54c1\u3092\u524a\u6e1b\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u308b\u3002<\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/www.hcftir.com\/wp-content\/uploads\/2026\/04\/Hench-Infrared-Dehumidifying-Cabinets-for-Bruker-FTIR-Spectrometers-4-1024x768.webp\" alt=\"Bruker FTIR \u306e\u5206\u5149\u8a08\u306e\u305f\u3081\u306e Hench \u306e\u8d64\u5916\u7dda\u9664\u6e7f\u306e\u30ad\u30e3\u30d3\u30cd\u30c3\u30c8\" class=\"wp-image-6452\" srcset=\"https:\/\/www.hcftir.com\/wp-content\/uploads\/2026\/04\/Hench-Infrared-Dehumidifying-Cabinets-for-Bruker-FTIR-Spectrometers-4-1024x768.webp 1024w, https:\/\/www.hcftir.com\/wp-content\/uploads\/2026\/04\/Hench-Infrared-Dehumidifying-Cabinets-for-Bruker-FTIR-Spectrometers-4-300x225.webp 300w, https:\/\/www.hcftir.com\/wp-content\/uploads\/2026\/04\/Hench-Infrared-Dehumidifying-Cabinets-for-Bruker-FTIR-Spectrometers-4-768x576.webp 768w, https:\/\/www.hcftir.com\/wp-content\/uploads\/2026\/04\/Hench-Infrared-Dehumidifying-Cabinets-for-Bruker-FTIR-Spectrometers-4-16x12.webp 16w, https:\/\/www.hcftir.com\/wp-content\/uploads\/2026\/04\/Hench-Infrared-Dehumidifying-Cabinets-for-Bruker-FTIR-Spectrometers-4.webp 1267w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>","protected":false},"excerpt":{"rendered":"<p>\u4e16\u754c\u3092\u30ea\u30fc\u30c9\u3059\u308b\u5206\u6790\u6a5f\u5668\u3067\u3042\u308b\u30d6\u30eb\u30ab\u30fcFTIR\u30b9\u30da\u30af\u30c8\u30ed\u30e1\u30fc\u30bf\u30fc\u306f\u3001\u88fd\u85ac\u3001\u5316\u5b66\u5de5\u5b66\u3001\u79d1\u5b66\u7814\u7a76\u306b\u304a\u3044\u3066\u4e0d\u53ef\u6b20\u306a\u3082\u306e\u3067\u3059\u3002\u3057\u304b\u3057\u3001\u30d3\u30fc\u30e0\u30b9\u30d7\u30ea\u30c3\u30bf\u30fc\u3001KBr\uff08\u81ed\u5316\u30ab\u30ea\u30a6\u30e0\uff09\u30a6\u30a4\u30f3\u30c9\u30a6\u3001\u5e72\u6e09\u8a08\u306a\u3069\u306e\u4e3b\u8981\u90e8\u54c1\u306f\u975e\u5e38\u306b\u5438\u6e7f\u6027\u304c\u9ad8\u3044\u3068\u3044\u3046\u6b20\u70b9\u304c\u3042\u308a\u307e\u3059\u3002\u904e\u5ea6\u306e\u6e7f\u6c17\u306f\u6f6e\u89e3\u3001\u5149\u8def\u306e\u9038\u8131\u3001\u4e0d\u53ef\u9006\u7684\u306a\u640d\u50b7\u3092\u5f15\u304d\u8d77\u3053\u3057\u3001\u3057\u3070\u3057\u3070\u6570\u4e07\u30c9\u30eb\u3092\u8d85\u3048\u308b\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u8cbb\u7528\u304c\u767a\u751f\u3057\u307e\u3059\u3002\u30d8\u30f3\u30c1\u306eMRD\/LAG\u30b7\u30ea\u30fc\u30ba\u8d64\u5916\u7dda\u96fb\u5b50\u9664\u6e7f\u30ad\u30e3\u30d3\u30cd\u30c3\u30c8\u306f\u3001FTIR\u30b7\u30b9\u30c6\u30e0\u306e\u30e9\u30a4\u30d5\u30b5\u30a4\u30af\u30eb\u5168\u4f53\u3092\u4fdd\u8b77\u3059\u308b\u305f\u3081\u306b\u7279\u5225\u306b\u8a2d\u8a08\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u6b63\u78ba\u306a\u6e7f\u5ea6\u5236\u5fa1\u3068\u30b7\u30fc\u30e0\u30ec\u30b9\u306a\u7d71\u5408\u3092\u63d0\u4f9b\u3059\u308b\u3053\u3068\u3067\u3001\u30d8\u30f3\u30c1\u306f\u4e16\u754c\u4e2d\u306e\u30d6\u30eb\u30ab\u30fc\u5206\u5149\u8a08\u306e\u4fe1\u983c\u3067\u304d\u308b\u4fdd\u8b77\u8005\u3068\u306a\u308a\u307e\u3057\u305f\u3002\u30b3\u30a2\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u306e\u5229\u70b9 1.\u8d85\u7cbe\u5bc6\u6e7f\u5ea6\u30b3\u30f3\u30c8\u30ed\u30fc\u30eb \u30d6\u30eb\u30ab\u30fc\u5206\u5149\u8a08\u306f\u901a\u5e3830%\uff5e40% RH\u306e\u4fdd\u7ba1\u74b0\u5883\u3092\u5fc5\u8981\u3068\u3057\u307e\u3059\u3002Hench\u306e\u30ad\u30e3\u30d3\u30cd\u30c3\u30c8\u306f[...]\u3092\u63d0\u4f9b\u3057\u307e\u3059\u3002<\/p>","protected":false},"author":1,"featured_media":6454,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[238],"tags":[],"class_list":["post-6449","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-news"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v24.4 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Protecting Precision: Hench Infrared Dehumidifying Cabinets for Bruker FTIR Spectrometers - Hench Technology<\/title>\n<meta name=\"description\" content=\"Protect your Bruker TENSOR II &amp; INVENIO with Hench Infrared Electronic Dehumidifying Cabinets. Precise \u00b13% RH control to prevent KBr window deliquescence. High-efficiency, low-energy storage for lab precision.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.hcftir.com\/ja\/protecting-precision-hench-infrared-dehumidifying-cabinets-for-bruker-ftir-spectrometers-article\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Protecting Precision: Hench Infrared Dehumidifying Cabinets for Bruker FTIR Spectrometers - Hench Technology\" \/>\n<meta property=\"og:description\" content=\"Protect your Bruker TENSOR II &amp; INVENIO with Hench Infrared Electronic Dehumidifying Cabinets. Precise \u00b13% RH control to prevent KBr window deliquescence. High-efficiency, low-energy storage for lab precision.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.hcftir.com\/ja\/protecting-precision-hench-infrared-dehumidifying-cabinets-for-bruker-ftir-spectrometers-article\/\" \/>\n<meta property=\"og:site_name\" content=\"Hench Technology\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/hcftir\" \/>\n<meta property=\"article:published_time\" content=\"2026-04-24T08:51:36+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-04-24T08:51:37+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.hcftir.com\/wp-content\/uploads\/2026\/04\/Hench-Infrared-Dehumidifying-Cabinets-for-Bruker-FTIR-Spectrometers.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"1267\" \/>\n\t<meta property=\"og:image:height\" content=\"950\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"author\" content=\"user\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"user\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"3\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/www.hcftir.com\/protecting-precision-hench-infrared-dehumidifying-cabinets-for-bruker-ftir-spectrometers-article\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/www.hcftir.com\/protecting-precision-hench-infrared-dehumidifying-cabinets-for-bruker-ftir-spectrometers-article\/\"},\"author\":{\"name\":\"user\",\"@id\":\"https:\/\/www.hcftir.com\/#\/schema\/person\/9a0e27c1156d5a1d4cb23dce2cc5ad36\"},\"headline\":\"Protecting Precision: Hench Infrared Dehumidifying Cabinets for Bruker FTIR Spectrometers\",\"datePublished\":\"2026-04-24T08:51:36+00:00\",\"dateModified\":\"2026-04-24T08:51:37+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/www.hcftir.com\/protecting-precision-hench-infrared-dehumidifying-cabinets-for-bruker-ftir-spectrometers-article\/\"},\"wordCount\":381,\"publisher\":{\"@id\":\"https:\/\/www.hcftir.com\/#organization\"},\"image\":{\"@id\":\"https:\/\/www.hcftir.com\/protecting-precision-hench-infrared-dehumidifying-cabinets-for-bruker-ftir-spectrometers-article\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.hcftir.com\/wp-content\/uploads\/2026\/04\/Hench-Infrared-Dehumidifying-Cabinets-for-Bruker-FTIR-Spectrometers.webp\",\"articleSection\":[\"News\"],\"inLanguage\":\"ja\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.hcftir.com\/protecting-precision-hench-infrared-dehumidifying-cabinets-for-bruker-ftir-spectrometers-article\/\",\"url\":\"https:\/\/www.hcftir.com\/protecting-precision-hench-infrared-dehumidifying-cabinets-for-bruker-ftir-spectrometers-article\/\",\"name\":\"Protecting Precision: Hench Infrared Dehumidifying Cabinets for Bruker FTIR Spectrometers - Hench Technology\",\"isPartOf\":{\"@id\":\"https:\/\/www.hcftir.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.hcftir.com\/protecting-precision-hench-infrared-dehumidifying-cabinets-for-bruker-ftir-spectrometers-article\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.hcftir.com\/protecting-precision-hench-infrared-dehumidifying-cabinets-for-bruker-ftir-spectrometers-article\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.hcftir.com\/wp-content\/uploads\/2026\/04\/Hench-Infrared-Dehumidifying-Cabinets-for-Bruker-FTIR-Spectrometers.webp\",\"datePublished\":\"2026-04-24T08:51:36+00:00\",\"dateModified\":\"2026-04-24T08:51:37+00:00\",\"description\":\"Protect your Bruker TENSOR II & INVENIO with Hench Infrared Electronic Dehumidifying Cabinets. Precise \u00b13% RH control to prevent KBr window deliquescence. High-efficiency, low-energy storage for lab precision.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.hcftir.com\/protecting-precision-hench-infrared-dehumidifying-cabinets-for-bruker-ftir-spectrometers-article\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.hcftir.com\/protecting-precision-hench-infrared-dehumidifying-cabinets-for-bruker-ftir-spectrometers-article\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\/\/www.hcftir.com\/protecting-precision-hench-infrared-dehumidifying-cabinets-for-bruker-ftir-spectrometers-article\/#primaryimage\",\"url\":\"https:\/\/www.hcftir.com\/wp-content\/uploads\/2026\/04\/Hench-Infrared-Dehumidifying-Cabinets-for-Bruker-FTIR-Spectrometers.webp\",\"contentUrl\":\"https:\/\/www.hcftir.com\/wp-content\/uploads\/2026\/04\/Hench-Infrared-Dehumidifying-Cabinets-for-Bruker-FTIR-Spectrometers.webp\",\"width\":1267,\"height\":950,\"caption\":\"Hench Infrared Dehumidifying Cabinets for Bruker FTIR Spectrometers\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.hcftir.com\/protecting-precision-hench-infrared-dehumidifying-cabinets-for-bruker-ftir-spectrometers-article\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.hcftir.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Protecting Precision: Hench Infrared Dehumidifying Cabinets for Bruker FTIR Spectrometers\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.hcftir.com\/#website\",\"url\":\"https:\/\/www.hcftir.com\/\",\"name\":\"Hench Technology\",\"description\":\"Hench Technology\",\"publisher\":{\"@id\":\"https:\/\/www.hcftir.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.hcftir.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.hcftir.com\/#organization\",\"name\":\"Tianjin Hench Technology Co., Ltd.\",\"url\":\"https:\/\/www.hcftir.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\/\/www.hcftir.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.hcftir.com\/wp-content\/uploads\/2025\/08\/cropped-cropped-Tianjin-Hench-Technology-Co.-Ltd.-logo-FTIR-instruments-and-laboratory-sample-preparation-tools-manufacturer.webp\",\"contentUrl\":\"https:\/\/www.hcftir.com\/wp-content\/uploads\/2025\/08\/cropped-cropped-Tianjin-Hench-Technology-Co.-Ltd.-logo-FTIR-instruments-and-laboratory-sample-preparation-tools-manufacturer.webp\",\"width\":512,\"height\":512,\"caption\":\"Tianjin Hench Technology Co., Ltd.\"},\"image\":{\"@id\":\"https:\/\/www.hcftir.com\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/hcftir\"]},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.hcftir.com\/#\/schema\/person\/9a0e27c1156d5a1d4cb23dce2cc5ad36\",\"name\":\"user\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\/\/www.hcftir.com\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/b58996c504c5638798eb6b511e6f49af?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/b58996c504c5638798eb6b511e6f49af?s=96&d=mm&r=g\",\"caption\":\"user\"},\"url\":\"https:\/\/www.hcftir.com\/ja\/author\/user\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Protecting Precision: Hench Infrared Dehumidifying Cabinets for Bruker FTIR Spectrometers - Hench Technology","description":"Protect your Bruker TENSOR II & INVENIO with Hench Infrared Electronic Dehumidifying Cabinets. Precise \u00b13% RH control to prevent KBr window deliquescence. High-efficiency, low-energy storage for lab precision.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.hcftir.com\/ja\/protecting-precision-hench-infrared-dehumidifying-cabinets-for-bruker-ftir-spectrometers-article\/","og_locale":"ja_JP","og_type":"article","og_title":"Protecting Precision: Hench Infrared Dehumidifying Cabinets for Bruker FTIR Spectrometers - Hench Technology","og_description":"Protect your Bruker TENSOR II & INVENIO with Hench Infrared Electronic Dehumidifying Cabinets. Precise \u00b13% RH control to prevent KBr window deliquescence. High-efficiency, low-energy storage for lab precision.","og_url":"https:\/\/www.hcftir.com\/ja\/protecting-precision-hench-infrared-dehumidifying-cabinets-for-bruker-ftir-spectrometers-article\/","og_site_name":"Hench Technology","article_publisher":"https:\/\/www.facebook.com\/hcftir","article_published_time":"2026-04-24T08:51:36+00:00","article_modified_time":"2026-04-24T08:51:37+00:00","og_image":[{"width":1267,"height":950,"url":"https:\/\/www.hcftir.com\/wp-content\/uploads\/2026\/04\/Hench-Infrared-Dehumidifying-Cabinets-for-Bruker-FTIR-Spectrometers.webp","type":"image\/webp"}],"author":"user","twitter_card":"summary_large_image","twitter_misc":{"Written by":"user","Est. reading time":"3\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.hcftir.com\/protecting-precision-hench-infrared-dehumidifying-cabinets-for-bruker-ftir-spectrometers-article\/#article","isPartOf":{"@id":"https:\/\/www.hcftir.com\/protecting-precision-hench-infrared-dehumidifying-cabinets-for-bruker-ftir-spectrometers-article\/"},"author":{"name":"user","@id":"https:\/\/www.hcftir.com\/#\/schema\/person\/9a0e27c1156d5a1d4cb23dce2cc5ad36"},"headline":"Protecting Precision: Hench Infrared Dehumidifying Cabinets for Bruker FTIR Spectrometers","datePublished":"2026-04-24T08:51:36+00:00","dateModified":"2026-04-24T08:51:37+00:00","mainEntityOfPage":{"@id":"https:\/\/www.hcftir.com\/protecting-precision-hench-infrared-dehumidifying-cabinets-for-bruker-ftir-spectrometers-article\/"},"wordCount":381,"publisher":{"@id":"https:\/\/www.hcftir.com\/#organization"},"image":{"@id":"https:\/\/www.hcftir.com\/protecting-precision-hench-infrared-dehumidifying-cabinets-for-bruker-ftir-spectrometers-article\/#primaryimage"},"thumbnailUrl":"https:\/\/www.hcftir.com\/wp-content\/uploads\/2026\/04\/Hench-Infrared-Dehumidifying-Cabinets-for-Bruker-FTIR-Spectrometers.webp","articleSection":["News"],"inLanguage":"ja"},{"@type":"WebPage","@id":"https:\/\/www.hcftir.com\/protecting-precision-hench-infrared-dehumidifying-cabinets-for-bruker-ftir-spectrometers-article\/","url":"https:\/\/www.hcftir.com\/protecting-precision-hench-infrared-dehumidifying-cabinets-for-bruker-ftir-spectrometers-article\/","name":"Protecting Precision: Hench Infrared Dehumidifying Cabinets for Bruker FTIR Spectrometers - Hench Technology","isPartOf":{"@id":"https:\/\/www.hcftir.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.hcftir.com\/protecting-precision-hench-infrared-dehumidifying-cabinets-for-bruker-ftir-spectrometers-article\/#primaryimage"},"image":{"@id":"https:\/\/www.hcftir.com\/protecting-precision-hench-infrared-dehumidifying-cabinets-for-bruker-ftir-spectrometers-article\/#primaryimage"},"thumbnailUrl":"https:\/\/www.hcftir.com\/wp-content\/uploads\/2026\/04\/Hench-Infrared-Dehumidifying-Cabinets-for-Bruker-FTIR-Spectrometers.webp","datePublished":"2026-04-24T08:51:36+00:00","dateModified":"2026-04-24T08:51:37+00:00","description":"Protect your Bruker TENSOR II & INVENIO with Hench Infrared Electronic Dehumidifying Cabinets. Precise \u00b13% RH control to prevent KBr window deliquescence. High-efficiency, low-energy storage for lab precision.","breadcrumb":{"@id":"https:\/\/www.hcftir.com\/protecting-precision-hench-infrared-dehumidifying-cabinets-for-bruker-ftir-spectrometers-article\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.hcftir.com\/protecting-precision-hench-infrared-dehumidifying-cabinets-for-bruker-ftir-spectrometers-article\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.hcftir.com\/protecting-precision-hench-infrared-dehumidifying-cabinets-for-bruker-ftir-spectrometers-article\/#primaryimage","url":"https:\/\/www.hcftir.com\/wp-content\/uploads\/2026\/04\/Hench-Infrared-Dehumidifying-Cabinets-for-Bruker-FTIR-Spectrometers.webp","contentUrl":"https:\/\/www.hcftir.com\/wp-content\/uploads\/2026\/04\/Hench-Infrared-Dehumidifying-Cabinets-for-Bruker-FTIR-Spectrometers.webp","width":1267,"height":950,"caption":"Hench Infrared Dehumidifying Cabinets for Bruker FTIR Spectrometers"},{"@type":"BreadcrumbList","@id":"https:\/\/www.hcftir.com\/protecting-precision-hench-infrared-dehumidifying-cabinets-for-bruker-ftir-spectrometers-article\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.hcftir.com\/"},{"@type":"ListItem","position":2,"name":"Protecting Precision: Hench Infrared Dehumidifying Cabinets for Bruker FTIR Spectrometers"}]},{"@type":"WebSite","@id":"https:\/\/www.hcftir.com\/#website","url":"https:\/\/www.hcftir.com\/","name":"Hench Technology","description":"Hench Technology","publisher":{"@id":"https:\/\/www.hcftir.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.hcftir.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Organization","@id":"https:\/\/www.hcftir.com\/#organization","name":"Tianjin Hench Technology Co., Ltd.","url":"https:\/\/www.hcftir.com\/","logo":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.hcftir.com\/#\/schema\/logo\/image\/","url":"https:\/\/www.hcftir.com\/wp-content\/uploads\/2025\/08\/cropped-cropped-Tianjin-Hench-Technology-Co.-Ltd.-logo-FTIR-instruments-and-laboratory-sample-preparation-tools-manufacturer.webp","contentUrl":"https:\/\/www.hcftir.com\/wp-content\/uploads\/2025\/08\/cropped-cropped-Tianjin-Hench-Technology-Co.-Ltd.-logo-FTIR-instruments-and-laboratory-sample-preparation-tools-manufacturer.webp","width":512,"height":512,"caption":"Tianjin Hench Technology Co., Ltd."},"image":{"@id":"https:\/\/www.hcftir.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/hcftir"]},{"@type":"Person","@id":"https:\/\/www.hcftir.com\/#\/schema\/person\/9a0e27c1156d5a1d4cb23dce2cc5ad36","name":"user","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.hcftir.com\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/b58996c504c5638798eb6b511e6f49af?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/b58996c504c5638798eb6b511e6f49af?s=96&d=mm&r=g","caption":"user"},"url":"https:\/\/www.hcftir.com\/ja\/author\/user\/"}]}},"_links":{"self":[{"href":"https:\/\/www.hcftir.com\/ja\/wp-json\/wp\/v2\/posts\/6449","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.hcftir.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.hcftir.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.hcftir.com\/ja\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.hcftir.com\/ja\/wp-json\/wp\/v2\/comments?post=6449"}],"version-history":[{"count":1,"href":"https:\/\/www.hcftir.com\/ja\/wp-json\/wp\/v2\/posts\/6449\/revisions"}],"predecessor-version":[{"id":6455,"href":"https:\/\/www.hcftir.com\/ja\/wp-json\/wp\/v2\/posts\/6449\/revisions\/6455"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.hcftir.com\/ja\/wp-json\/wp\/v2\/media\/6454"}],"wp:attachment":[{"href":"https:\/\/www.hcftir.com\/ja\/wp-json\/wp\/v2\/media?parent=6449"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.hcftir.com\/ja\/wp-json\/wp\/v2\/categories?post=6449"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.hcftir.com\/ja\/wp-json\/wp\/v2\/tags?post=6449"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}