{"id":6320,"date":"2026-03-13T06:40:50","date_gmt":"2026-03-13T06:40:50","guid":{"rendered":"https:\/\/www.hcftir.com\/?p=6320"},"modified":"2026-03-13T06:40:50","modified_gmt":"2026-03-13T06:40:50","slug":"system-analysis-of-ftir-equipped-with-znse-zinc-selenide-atr","status":"publish","type":"post","link":"https:\/\/www.hcftir.com\/es\/system-analysis-of-ftir-equipped-with-znse-zinc-selenide-atr-article\/","title":{"rendered":"An\u00e1lisis del sistema FTIR equipado con ZnSe (seleniuro de zinc) ATR"},"content":{"rendered":"<p>Los sistemas FTIR equipados con un accesorio ATR (reflexi\u00f3n total atenuada) de ZnSe se utilizan ampliamente para el an\u00e1lisis r\u00e1pido de superficies de diversos materiales. Esta configuraci\u00f3n permite obtener espectros infrarrojos directamente a partir de s\u00f3lidos, l\u00edquidos, pastas y pel\u00edculas sin necesidad de procedimientos complejos de preparaci\u00f3n de muestras, como el prensado de gr\u00e1nulos o la disoluci\u00f3n. El m\u00f3dulo ATR de ZnSe proporciona datos espectrales fiables al tiempo que mantiene un buen rendimiento se\u00f1al-ruido y eficiencia operativa.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/www.hcftir.com\/wp-content\/uploads\/2026\/03\/FTIR-ZnSe-ATR.webp\" alt=\"FTIR ZnSe ATR 2\" class=\"wp-image-6325\" srcset=\"https:\/\/www.hcftir.com\/wp-content\/uploads\/2026\/03\/FTIR-ZnSe-ATR.webp 1024w, https:\/\/www.hcftir.com\/wp-content\/uploads\/2026\/03\/FTIR-ZnSe-ATR-300x225.webp 300w, https:\/\/www.hcftir.com\/wp-content\/uploads\/2026\/03\/FTIR-ZnSe-ATR-768x576.webp 768w, https:\/\/www.hcftir.com\/wp-content\/uploads\/2026\/03\/FTIR-ZnSe-ATR-16x12.webp 16w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Principios b\u00e1sicos y estructura<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Mecanismo ATR (reflexi\u00f3n total atenuada)<\/h3>\n\n\n\n<p>En el an\u00e1lisis ATR, la luz infrarroja sufre una reflexi\u00f3n interna total dentro del cristal de ZnSe. Durante este proceso, se genera una onda evanescente en la interfaz entre el cristal y la muestra. Esta onda evanescente penetra ligeramente en la superficie de la muestra, normalmente hasta una profundidad de 1-5 \u03bcm.<\/p>\n\n\n\n<p>Cuando la muestra est\u00e1 en estrecho contacto con la superficie del cristal, grupos moleculares espec\u00edficos absorben la radiaci\u00f3n infrarroja a longitudes de onda caracter\u00edsticas. La absorci\u00f3n provoca una reducci\u00f3n de la intensidad del haz infrarrojo reflejado, lo que permite al sistema FTIR registrar el espectro caracter\u00edstico de la muestra.<\/p>\n\n\n\n<p>Dado que el ATR mide la interacci\u00f3n superficial entre el haz de infrarrojos y la muestra, es posible analizar directamente materiales como s\u00f3lidos, l\u00edquidos, pastas y pel\u00edculas finas sin necesidad de complicados tratamientos previos.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">M\u00f3dulo ATR de ZnSe<\/h3>\n\n\n\n<p>El m\u00f3dulo ATR de ZnSe suele adoptar una estructura de prisma de reflexi\u00f3n simple o m\u00faltiple, con un \u00e1ngulo de incidencia que suele rondar los 45\u00b0. Est\u00e1 integrado en la c\u00e1mara de muestras FTIR y suele incluir un cabezal de presi\u00f3n controlable para garantizar un contacto adecuado entre la muestra y el cristal.<\/p>\n\n\n\n<p>Los cristales de ZnSe suelen producirse mediante deposici\u00f3n qu\u00edmica en fase vapor (CVD). El cristal resultante es un material policristalino transparente de color amarillo claro. A menudo se aplica un revestimiento reflectante para aumentar el flujo de luz infrarroja y mejorar la eficacia \u00f3ptica del sistema ATR.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/www.hcftir.com\/wp-content\/uploads\/2026\/03\/FTIR-ZnSe-ATR-2.webp\" alt=\"FTIR ZnSe ATR 2\" class=\"wp-image-6321\" srcset=\"https:\/\/www.hcftir.com\/wp-content\/uploads\/2026\/03\/FTIR-ZnSe-ATR-2.webp 1024w, https:\/\/www.hcftir.com\/wp-content\/uploads\/2026\/03\/FTIR-ZnSe-ATR-2-300x225.webp 300w, https:\/\/www.hcftir.com\/wp-content\/uploads\/2026\/03\/FTIR-ZnSe-ATR-2-768x576.webp 768w, https:\/\/www.hcftir.com\/wp-content\/uploads\/2026\/03\/FTIR-ZnSe-ATR-2-16x12.webp 16w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Saber por qu\u00e9<\/h2>\n\n\n\n<p>En un accesorio ATR, el \u00e1rea de contacto efectiva entre la muestra y el cristal ATR es muy peque\u00f1a. La aplicaci\u00f3n de una presi\u00f3n controlada ayuda a que la muestra entre en estrecho contacto con la superficie del cristal. Incluso cuando la luz infrarroja s\u00f3lo experimenta una reflexi\u00f3n efectiva dentro del cristal ATR, pueden obtenerse espectros de alta calidad.<\/p>\n\n\n\n<p>Los accesorios ATR de reflexi\u00f3n simple son adecuados para el ensayo de una amplia gama de materiales, entre los que se incluyen:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Muestras s\u00f3lidas<\/li>\n\n\n\n<li>Fibras<\/li>\n\n\n\n<li>Pol\u00edmeros duros<\/li>\n\n\n\n<li>L\u00e1minas de pintura<\/li>\n\n\n\n<li>Revestimientos finos sobre superficies de vidrio o metal<\/li>\n\n\n\n<li>L\u00edquidos traza<\/li>\n<\/ul>\n\n\n\n<p>La plataforma de cristal del accesorio ATR normalmente s\u00f3lo expone un peque\u00f1o plano de unos 3 mm. Por lo tanto, durante la medici\u00f3n, se recomienda que la superficie plana de la muestra est\u00e9 en estrecho contacto con la zona del cristal.<\/p>\n\n\n\n<p>Cuando se utiliza ZnSe como material cristalino, la presi\u00f3n preestablecida suele ser de unos 20 kg. En estas condiciones, las muestras l\u00edquidas que pueden someterse a ensayo suelen estar comprendidas en un intervalo de pH de 5-9. No deben utilizarse \u00e1cidos ni bases fuertes con cristales de ZnSe. Los \u00e1cidos fuertes y las bases fuertes no deben ensayarse con cristales de ZnSe.<\/p>\n\n\n\n<p>En comparaci\u00f3n, los cristales de diamante soportan una mayor presi\u00f3n y tienen una gran resistencia qu\u00edmica. Pueden analizar l\u00edquidos en un intervalo de pH m\u00e1s amplio, de 1 a 14, y son adecuados para muestras m\u00e1s duras. Otros materiales, como ZnSe, AMTIR, Ge y Si, tambi\u00e9n pueden utilizarse como cristales de reflexi\u00f3n ATR en funci\u00f3n de los requisitos anal\u00edticos.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"733\" height=\"648\" src=\"https:\/\/www.hcftir.com\/wp-content\/uploads\/2026\/03\/FTIR-ZnSe-ATR-3.webp\" alt=\"FTIR ZnSe ATR 2\" class=\"wp-image-6322\" srcset=\"https:\/\/www.hcftir.com\/wp-content\/uploads\/2026\/03\/FTIR-ZnSe-ATR-3.webp 733w, https:\/\/www.hcftir.com\/wp-content\/uploads\/2026\/03\/FTIR-ZnSe-ATR-3-300x265.webp 300w, https:\/\/www.hcftir.com\/wp-content\/uploads\/2026\/03\/FTIR-ZnSe-ATR-3-14x12.webp 14w\" sizes=\"auto, (max-width: 733px) 100vw, 733px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Ventajas, escenarios aplicables y limitaciones<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Principales ventajas<\/h3>\n\n\n\n<p>Los accesorios ATR de ZnSe ofrecen varias ventajas pr\u00e1cticas:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Menor coste en comparaci\u00f3n con el ATR de diamante<\/li>\n\n\n\n<li>Alta transmitancia del infrarrojo medio y buena relaci\u00f3n se\u00f1al\/ruido<\/li>\n\n\n\n<li>No requiere una preparaci\u00f3n compleja de la muestra; los l\u00edquidos pueden dejarse caer directamente sobre la superficie del cristal y los s\u00f3lidos pueden presionarse ligeramente<\/li>\n\n\n\n<li>Adecuado para pruebas r\u00e1pidas por lotes<\/li>\n\n\n\n<li>Buena compatibilidad con accesorios de calefacci\u00f3n o baja temperatura<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Aplicaciones t\u00edpicas<\/h3>\n\n\n\n<p><strong>Industria farmac\u00e9utica<\/strong><\/p>\n\n\n\n<p>El ZnSe ATR se utiliza habitualmente para el an\u00e1lisis de pomadas, geles, recubrimientos de comprimidos y para la identificaci\u00f3n cualitativa r\u00e1pida de materias primas farmac\u00e9uticas.<\/p>\n\n\n\n<p><strong>Materiales polim\u00e9ricos<\/strong><\/p>\n\n\n\n<p>Las aplicaciones incluyen la comprobaci\u00f3n de pel\u00edculas de pl\u00e1stico, materiales de caucho y componentes superficiales de adhesivos.<\/p>\n\n\n\n<p><strong>Industria qu\u00edmica<\/strong><\/p>\n\n\n\n<p>Se utiliza ampliamente para el control de calidad de aceites, revestimientos, tintas y emulsiones.<\/p>\n\n\n\n<p><strong>Industria alimentaria<\/strong><\/p>\n\n\n\n<p>El ATR de ZnSe puede aplicarse para detectar componentes y deterioro en aceites, salsas y bebidas.<\/p>\n\n\n\n<p>Para los laboratorios que requieren una mayor eficacia de medici\u00f3n o una mejor interacci\u00f3n de la se\u00f1al, accesorios como el <a href=\"https:\/\/www.hcftir.com\/multi-atr-reflective-attachment-product\/\">Accesorio reflectante Multi ATR<\/a> pueden proporcionar v\u00edas de reflexi\u00f3n mejoradas y una mayor flexibilidad anal\u00edtica.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Limitaciones<\/h3>\n\n\n\n<p>Aunque los cristales ATR de ZnSe se utilizan ampliamente, hay que tener en cuenta varias limitaciones:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>El cristal es relativamente blando y propenso a rayarse<\/li>\n\n\n\n<li>La resistencia a la corrosi\u00f3n qu\u00edmica es m\u00e1s d\u00e9bil que la de los cristales de diamante<\/li>\n\n\n\n<li>La sensibilidad de las muestras muy absorbentes, como las soluciones oscuras muy concentradas, es inferior a la del ATR de germanio (Ge).<\/li>\n\n\n\n<li>No es adecuado para muestras muy abrasivas como polvos minerales<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Puntos clave para el funcionamiento y el mantenimiento<\/h2>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/www.hcftir.com\/wp-content\/uploads\/2026\/03\/FTIR-ZnSe-ATR-4.webp\" alt=\"FTIR ZnSe ATR 2\" class=\"wp-image-6323\" srcset=\"https:\/\/www.hcftir.com\/wp-content\/uploads\/2026\/03\/FTIR-ZnSe-ATR-4.webp 1024w, https:\/\/www.hcftir.com\/wp-content\/uploads\/2026\/03\/FTIR-ZnSe-ATR-4-300x225.webp 300w, https:\/\/www.hcftir.com\/wp-content\/uploads\/2026\/03\/FTIR-ZnSe-ATR-4-768x576.webp 768w, https:\/\/www.hcftir.com\/wp-content\/uploads\/2026\/03\/FTIR-ZnSe-ATR-4-16x12.webp 16w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Preparaci\u00f3n de la muestra<\/h3>\n\n\n\n<p>La superficie s\u00f3lida debe ser plana para garantizar un buen contacto con el cristal. Las muestras l\u00edquidas no deben contener burbujas y deben evitarse los medios fuertemente corrosivos.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Limpieza<\/h3>\n\n\n\n<p>Tras la prueba, la superficie del cristal debe limpiarse con etanol absoluto o alcohol isoprop\u00edlico y limpiarse suavemente con un pa\u00f1o suave no tejido. No deben utilizarse acetona ni agentes de limpieza alcalinos fuertes.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Control de la presi\u00f3n<\/h3>\n\n\n\n<p>Debe utilizarse el cabezal de presi\u00f3n adecuado para evitar una presi\u00f3n excesiva sobre el cristal. Las muestras de polvo deben aplicarse como una capa fina y uniformemente distribuida.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Mantenimiento diario<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Limpiar el cristal inmediatamente despu\u00e9s de la prueba<\/li>\n\n\n\n<li>Sella y protege el cristal de la humedad cuando no se utiliza durante periodos prolongados<\/li>\n\n\n\n<li>Evitar fluctuaciones dr\u00e1sticas de temperatura<\/li>\n\n\n\n<li>No toque la superficie del cristal con objetos duros<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Correcci\u00f3n del espectro<\/h3>\n\n\n\n<p>Debe realizarse una calibraci\u00f3n espectral peri\u00f3dica utilizando membranas de poliestireno o l\u00edquidos est\u00e1ndar. La sustracci\u00f3n de fondo ATR y la calibraci\u00f3n de la longitud de onda ayudan a mantener la precisi\u00f3n espectral.<\/p>\n\n\n\n<p>Tambi\u00e9n debe garantizarse un contacto adecuado de la muestra para evitar la desviaci\u00f3n de la l\u00ednea de base causada por un mal contacto del cristal.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Comparaci\u00f3n con otros cristales ATR<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Cristal<\/th><th>\u00cdndice de refracci\u00f3n<\/th><th>Rigidez<\/th><th>Muestras aplicables<\/th><th>Precio<\/th><\/tr><\/thead><tbody><tr><td>ZnSe<\/td><td>2.40<\/td><td>Medio<\/td><td>L\u00edquidos de absorci\u00f3n media-baja, s\u00f3lidos blandos, pastas<\/td><td>Medio<\/td><\/tr><tr><td>Diamante<\/td><td>2.41<\/td><td>Muy alta<\/td><td>Muestras duras y muy corrosivas<\/td><td>Alta<\/td><\/tr><tr><td>Ge<\/td><td>4.00<\/td><td>Bajo<\/td><td>Muestras muy absorbentes o de color oscuro<\/td><td>Moderadamente bajo<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p>Pie de foto: Comparaci\u00f3n de los materiales de cristal ATR m\u00e1s comunes utilizados en los accesorios FTIR.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/www.hcftir.com\/wp-content\/uploads\/2026\/03\/FTIR-ZnSe-ATR-5.webp\" alt=\"FTIR ZnSe ATR 2\" class=\"wp-image-6324\" srcset=\"https:\/\/www.hcftir.com\/wp-content\/uploads\/2026\/03\/FTIR-ZnSe-ATR-5.webp 1024w, https:\/\/www.hcftir.com\/wp-content\/uploads\/2026\/03\/FTIR-ZnSe-ATR-5-300x225.webp 300w, https:\/\/www.hcftir.com\/wp-content\/uploads\/2026\/03\/FTIR-ZnSe-ATR-5-768x576.webp 768w, https:\/\/www.hcftir.com\/wp-content\/uploads\/2026\/03\/FTIR-ZnSe-ATR-5-16x12.webp 16w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Selecci\u00f3n y compatibilidad con espectr\u00f3metros<\/h2>\n\n\n\n<p>Los principales instrumentos FTIR suelen admitir m\u00f3dulos ATR de ZnSe est\u00e1ndar, que pueden instalarse directamente sin necesidad de recalibrar la ruta \u00f3ptica.<\/p>\n\n\n\n<p>Si es necesario medir muestras muy absorbentes, debe darse prioridad al ATR multirreflexi\u00f3n de ZnSe o Ge. Cuando se analizan muestras que contienen \u00e1cidos fuertes o agentes oxidantes fuertes, se recomienda el ATR de diamante debido a su mayor resistencia qu\u00edmica.<\/p>\n\n\n\n<p>En el modo ATR, la intensidad del pico espectral est\u00e1 relacionada con el n\u00famero de onda debido a las diferencias en la profundidad de penetraci\u00f3n. Por lo tanto, el an\u00e1lisis cuantitativo suele requerir algoritmos de correcci\u00f3n ATR como la correcci\u00f3n de Eriksson.<\/p>\n\n\n\n<p>Durante el an\u00e1lisis, tambi\u00e9n debe mantenerse una sustracci\u00f3n de fondo constante para evitar la desviaci\u00f3n de la l\u00ednea de base causada por un contacto deficiente entre la muestra y el cristal ATR.<\/p>","protected":false},"excerpt":{"rendered":"<p>Los sistemas FTIR equipados con un accesorio ATR (reflexi\u00f3n total atenuada) de ZnSe se utilizan ampliamente para el an\u00e1lisis r\u00e1pido de superficies de diversos materiales. Esta configuraci\u00f3n permite obtener espectros infrarrojos directamente a partir de s\u00f3lidos, l\u00edquidos, pastas y pel\u00edculas sin necesidad de procedimientos complejos de preparaci\u00f3n de muestras, como el prensado de gr\u00e1nulos o la disoluci\u00f3n. El m\u00f3dulo ATR de ZnSe proporciona datos espectrales fiables [...]<\/p>","protected":false},"author":1,"featured_media":6325,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[238],"tags":[],"class_list":["post-6320","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-news"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v24.4 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>System Analysis of FTIR Equipped with ZnSe (Zinc Selenide) ATR - Hench Technology<\/title>\n<meta name=\"description\" content=\"Overview of FTIR systems equipped with ZnSe ATR, including principles, structure, applications, limitations, and ATR crystal comparison.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.hcftir.com\/es\/system-analysis-of-ftir-equipped-with-znse-zinc-selenide-atr-article\/\" \/>\n<meta property=\"og:locale\" content=\"es_ES\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"System Analysis of FTIR Equipped with ZnSe (Zinc Selenide) ATR - Hench Technology\" \/>\n<meta property=\"og:description\" content=\"Overview of FTIR systems equipped with ZnSe ATR, including principles, structure, applications, limitations, and ATR crystal comparison.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.hcftir.com\/es\/system-analysis-of-ftir-equipped-with-znse-zinc-selenide-atr-article\/\" \/>\n<meta property=\"og:site_name\" content=\"Hench Technology\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/hcftir\" \/>\n<meta property=\"article:published_time\" content=\"2026-03-13T06:40:50+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.hcftir.com\/wp-content\/uploads\/2026\/03\/FTIR-ZnSe-ATR.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"1024\" \/>\n\t<meta property=\"og:image:height\" content=\"768\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"author\" content=\"user\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"user\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"6 minutos\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/www.hcftir.com\/system-analysis-of-ftir-equipped-with-znse-zinc-selenide-atr-article\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/www.hcftir.com\/system-analysis-of-ftir-equipped-with-znse-zinc-selenide-atr-article\/\"},\"author\":{\"name\":\"user\",\"@id\":\"https:\/\/www.hcftir.com\/#\/schema\/person\/9a0e27c1156d5a1d4cb23dce2cc5ad36\"},\"headline\":\"System Analysis of FTIR Equipped with ZnSe (Zinc Selenide) ATR\",\"datePublished\":\"2026-03-13T06:40:50+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/www.hcftir.com\/system-analysis-of-ftir-equipped-with-znse-zinc-selenide-atr-article\/\"},\"wordCount\":1045,\"publisher\":{\"@id\":\"https:\/\/www.hcftir.com\/#organization\"},\"image\":{\"@id\":\"https:\/\/www.hcftir.com\/system-analysis-of-ftir-equipped-with-znse-zinc-selenide-atr-article\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.hcftir.com\/wp-content\/uploads\/2026\/03\/FTIR-ZnSe-ATR.webp\",\"articleSection\":[\"News\"],\"inLanguage\":\"es\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.hcftir.com\/system-analysis-of-ftir-equipped-with-znse-zinc-selenide-atr-article\/\",\"url\":\"https:\/\/www.hcftir.com\/system-analysis-of-ftir-equipped-with-znse-zinc-selenide-atr-article\/\",\"name\":\"System Analysis of FTIR Equipped with ZnSe (Zinc Selenide) ATR - Hench Technology\",\"isPartOf\":{\"@id\":\"https:\/\/www.hcftir.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.hcftir.com\/system-analysis-of-ftir-equipped-with-znse-zinc-selenide-atr-article\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.hcftir.com\/system-analysis-of-ftir-equipped-with-znse-zinc-selenide-atr-article\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.hcftir.com\/wp-content\/uploads\/2026\/03\/FTIR-ZnSe-ATR.webp\",\"datePublished\":\"2026-03-13T06:40:50+00:00\",\"description\":\"Overview of FTIR systems equipped with ZnSe ATR, including principles, structure, applications, limitations, and ATR crystal comparison.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.hcftir.com\/system-analysis-of-ftir-equipped-with-znse-zinc-selenide-atr-article\/#breadcrumb\"},\"inLanguage\":\"es\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.hcftir.com\/system-analysis-of-ftir-equipped-with-znse-zinc-selenide-atr-article\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\/\/www.hcftir.com\/system-analysis-of-ftir-equipped-with-znse-zinc-selenide-atr-article\/#primaryimage\",\"url\":\"https:\/\/www.hcftir.com\/wp-content\/uploads\/2026\/03\/FTIR-ZnSe-ATR.webp\",\"contentUrl\":\"https:\/\/www.hcftir.com\/wp-content\/uploads\/2026\/03\/FTIR-ZnSe-ATR.webp\",\"width\":1024,\"height\":768,\"caption\":\"FTIR ZnSe ATR 2\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.hcftir.com\/system-analysis-of-ftir-equipped-with-znse-zinc-selenide-atr-article\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.hcftir.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"System Analysis of FTIR Equipped with ZnSe (Zinc Selenide) ATR\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.hcftir.com\/#website\",\"url\":\"https:\/\/www.hcftir.com\/\",\"name\":\"Hench Technology\",\"description\":\"Hench Technology\",\"publisher\":{\"@id\":\"https:\/\/www.hcftir.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.hcftir.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"es\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.hcftir.com\/#organization\",\"name\":\"Tianjin Hench Technology Co., Ltd.\",\"url\":\"https:\/\/www.hcftir.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\/\/www.hcftir.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.hcftir.com\/wp-content\/uploads\/2025\/08\/cropped-cropped-Tianjin-Hench-Technology-Co.-Ltd.-logo-FTIR-instruments-and-laboratory-sample-preparation-tools-manufacturer.webp\",\"contentUrl\":\"https:\/\/www.hcftir.com\/wp-content\/uploads\/2025\/08\/cropped-cropped-Tianjin-Hench-Technology-Co.-Ltd.-logo-FTIR-instruments-and-laboratory-sample-preparation-tools-manufacturer.webp\",\"width\":512,\"height\":512,\"caption\":\"Tianjin Hench Technology Co., Ltd.\"},\"image\":{\"@id\":\"https:\/\/www.hcftir.com\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/hcftir\"]},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.hcftir.com\/#\/schema\/person\/9a0e27c1156d5a1d4cb23dce2cc5ad36\",\"name\":\"user\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\/\/www.hcftir.com\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/b58996c504c5638798eb6b511e6f49af?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/b58996c504c5638798eb6b511e6f49af?s=96&d=mm&r=g\",\"caption\":\"user\"},\"url\":\"https:\/\/www.hcftir.com\/es\/author\/user\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"System Analysis of FTIR Equipped with ZnSe (Zinc Selenide) ATR - Hench Technology","description":"Overview of FTIR systems equipped with ZnSe ATR, including principles, structure, applications, limitations, and ATR crystal comparison.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.hcftir.com\/es\/system-analysis-of-ftir-equipped-with-znse-zinc-selenide-atr-article\/","og_locale":"es_ES","og_type":"article","og_title":"System Analysis of FTIR Equipped with ZnSe (Zinc Selenide) ATR - Hench Technology","og_description":"Overview of FTIR systems equipped with ZnSe ATR, including principles, structure, applications, limitations, and ATR crystal comparison.","og_url":"https:\/\/www.hcftir.com\/es\/system-analysis-of-ftir-equipped-with-znse-zinc-selenide-atr-article\/","og_site_name":"Hench Technology","article_publisher":"https:\/\/www.facebook.com\/hcftir","article_published_time":"2026-03-13T06:40:50+00:00","og_image":[{"width":1024,"height":768,"url":"https:\/\/www.hcftir.com\/wp-content\/uploads\/2026\/03\/FTIR-ZnSe-ATR.webp","type":"image\/webp"}],"author":"user","twitter_card":"summary_large_image","twitter_misc":{"Written by":"user","Est. reading time":"6 minutos"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.hcftir.com\/system-analysis-of-ftir-equipped-with-znse-zinc-selenide-atr-article\/#article","isPartOf":{"@id":"https:\/\/www.hcftir.com\/system-analysis-of-ftir-equipped-with-znse-zinc-selenide-atr-article\/"},"author":{"name":"user","@id":"https:\/\/www.hcftir.com\/#\/schema\/person\/9a0e27c1156d5a1d4cb23dce2cc5ad36"},"headline":"System Analysis of FTIR Equipped with ZnSe (Zinc Selenide) ATR","datePublished":"2026-03-13T06:40:50+00:00","mainEntityOfPage":{"@id":"https:\/\/www.hcftir.com\/system-analysis-of-ftir-equipped-with-znse-zinc-selenide-atr-article\/"},"wordCount":1045,"publisher":{"@id":"https:\/\/www.hcftir.com\/#organization"},"image":{"@id":"https:\/\/www.hcftir.com\/system-analysis-of-ftir-equipped-with-znse-zinc-selenide-atr-article\/#primaryimage"},"thumbnailUrl":"https:\/\/www.hcftir.com\/wp-content\/uploads\/2026\/03\/FTIR-ZnSe-ATR.webp","articleSection":["News"],"inLanguage":"es"},{"@type":"WebPage","@id":"https:\/\/www.hcftir.com\/system-analysis-of-ftir-equipped-with-znse-zinc-selenide-atr-article\/","url":"https:\/\/www.hcftir.com\/system-analysis-of-ftir-equipped-with-znse-zinc-selenide-atr-article\/","name":"System Analysis of FTIR Equipped with ZnSe (Zinc Selenide) ATR - Hench Technology","isPartOf":{"@id":"https:\/\/www.hcftir.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.hcftir.com\/system-analysis-of-ftir-equipped-with-znse-zinc-selenide-atr-article\/#primaryimage"},"image":{"@id":"https:\/\/www.hcftir.com\/system-analysis-of-ftir-equipped-with-znse-zinc-selenide-atr-article\/#primaryimage"},"thumbnailUrl":"https:\/\/www.hcftir.com\/wp-content\/uploads\/2026\/03\/FTIR-ZnSe-ATR.webp","datePublished":"2026-03-13T06:40:50+00:00","description":"Overview of FTIR systems equipped with ZnSe ATR, including principles, structure, applications, limitations, and ATR crystal comparison.","breadcrumb":{"@id":"https:\/\/www.hcftir.com\/system-analysis-of-ftir-equipped-with-znse-zinc-selenide-atr-article\/#breadcrumb"},"inLanguage":"es","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.hcftir.com\/system-analysis-of-ftir-equipped-with-znse-zinc-selenide-atr-article\/"]}]},{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/www.hcftir.com\/system-analysis-of-ftir-equipped-with-znse-zinc-selenide-atr-article\/#primaryimage","url":"https:\/\/www.hcftir.com\/wp-content\/uploads\/2026\/03\/FTIR-ZnSe-ATR.webp","contentUrl":"https:\/\/www.hcftir.com\/wp-content\/uploads\/2026\/03\/FTIR-ZnSe-ATR.webp","width":1024,"height":768,"caption":"FTIR ZnSe ATR 2"},{"@type":"BreadcrumbList","@id":"https:\/\/www.hcftir.com\/system-analysis-of-ftir-equipped-with-znse-zinc-selenide-atr-article\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.hcftir.com\/"},{"@type":"ListItem","position":2,"name":"System Analysis of FTIR Equipped with ZnSe (Zinc Selenide) ATR"}]},{"@type":"WebSite","@id":"https:\/\/www.hcftir.com\/#website","url":"https:\/\/www.hcftir.com\/","name":"Hench Technology","description":"Hench Technology","publisher":{"@id":"https:\/\/www.hcftir.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.hcftir.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"es"},{"@type":"Organization","@id":"https:\/\/www.hcftir.com\/#organization","name":"Tianjin Hench Technology Co., Ltd.","url":"https:\/\/www.hcftir.com\/","logo":{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/www.hcftir.com\/#\/schema\/logo\/image\/","url":"https:\/\/www.hcftir.com\/wp-content\/uploads\/2025\/08\/cropped-cropped-Tianjin-Hench-Technology-Co.-Ltd.-logo-FTIR-instruments-and-laboratory-sample-preparation-tools-manufacturer.webp","contentUrl":"https:\/\/www.hcftir.com\/wp-content\/uploads\/2025\/08\/cropped-cropped-Tianjin-Hench-Technology-Co.-Ltd.-logo-FTIR-instruments-and-laboratory-sample-preparation-tools-manufacturer.webp","width":512,"height":512,"caption":"Tianjin Hench Technology Co., Ltd."},"image":{"@id":"https:\/\/www.hcftir.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/hcftir"]},{"@type":"Person","@id":"https:\/\/www.hcftir.com\/#\/schema\/person\/9a0e27c1156d5a1d4cb23dce2cc5ad36","name":"user","image":{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/www.hcftir.com\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/b58996c504c5638798eb6b511e6f49af?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/b58996c504c5638798eb6b511e6f49af?s=96&d=mm&r=g","caption":"user"},"url":"https:\/\/www.hcftir.com\/es\/author\/user\/"}]}},"_links":{"self":[{"href":"https:\/\/www.hcftir.com\/es\/wp-json\/wp\/v2\/posts\/6320","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.hcftir.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.hcftir.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.hcftir.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.hcftir.com\/es\/wp-json\/wp\/v2\/comments?post=6320"}],"version-history":[{"count":1,"href":"https:\/\/www.hcftir.com\/es\/wp-json\/wp\/v2\/posts\/6320\/revisions"}],"predecessor-version":[{"id":6326,"href":"https:\/\/www.hcftir.com\/es\/wp-json\/wp\/v2\/posts\/6320\/revisions\/6326"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.hcftir.com\/es\/wp-json\/wp\/v2\/media\/6325"}],"wp:attachment":[{"href":"https:\/\/www.hcftir.com\/es\/wp-json\/wp\/v2\/media?parent=6320"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.hcftir.com\/es\/wp-json\/wp\/v2\/categories?post=6320"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.hcftir.com\/es\/wp-json\/wp\/v2\/tags?post=6320"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}